ure testing range is from -60°C to +225°C. The control panel is knob-style and supports data storage. inTEST ATS-525 is the completely upgraded version of the old high/low temperature testing machine Thermonics T-2650BV!
Feature:
Conversion rate:
-40°C to +125°C, <12 seconds
+125°C to -40°C, <40 seconds
System airflow output: 5 scfm (2.4.7 l/s) - fixed flow rate
Temperature display and resolution: ±1°C
Temperature accuracy: ±1°C
Direct control of the tested device (DUT)
DUT control sensor: T-type or K-type thermocouple
Remote interface: IEEE.488, RS232
Thermal cap provides a local thermal testing environment to prevent the DUT from getting damp and condensation in the field
Compact and portable system, can be easily integrated into a desktop
Complies with CE standards