销售LUNA PSY-201 拉偏合成器

浏览次数:101

产品参数

选件 是否计量 发货周期 保修时间 成色
5天 90天 8成新
所在地 机身号 状态 资料下载
深圳市 完好
更新日期:2025-08-30
联系电话:0755-86016691

* 产品描述

LUNA PSY-201是一款确定性偏振控制器,也可作为偏振合成器/分析仪,能生成并保持任何偏振态(SOP),而与输入SOP无关。
特点:
将偏振控制器、偏振计和控制算法组合于一体,可作为SOP发生器或偏振分析仪。输出SOP可由斯托克斯参数定义,能手动调整到庞加莱球上任意点,也可优化与偏振相关的度量。具备快捷功能,可生成6个不同的SOP(0°、90°、±45°、RHC和LHC)用于穆勒矩阵计算。还支持编程的SOP迹线和可变速率偏振加扰。此外,禁用内部偏振控制器时,可作为在线偏振计,测量输入光束的瞬时SOP和偏振度(DOP),且有数据记录功能,可长期测量多达10亿个点的偏振变化。
波长范围为1480-1620nm或1280-1340nm,模拟带宽1兆赫,采样率高达4M样本/秒。生成的SOP稳定时间为1ms(稳定输入SOP),稳定性在稳定输入SOP时为0.1°,输入SOP变化<2π/s时为0.5°,输入SOP变化<10π/s时为2°。SOP测量不确定度在用户校准后为±0.25°,DOP测量不确定度工厂校准为±2%,用户校准为±0.5%。偏振消光比(PER)测量范围0到40分贝,分辨率为0.1分贝。

详细信息

LUNA PSY-201 is a deterministic polarization controller, which can also function as a polarization synthesizer/analyser. It can generate and maintain any polarization state (SOP), regardless of the input SOP.
Features:
It integrates a polarization controller, a polarization meter, and control algorithms, and can be used as an SOP generator or polarization analyzer. The output SOP can be defined by Stokes parameters and can be manually adjusted to any point on the Poincaré sphere, or optimized for polarization-related measurements. It has quick functions, capable of generating 6 different SOPs (0°, 90°, ±45°, RHC, and LHC) for Mueller matrix calculations. It also supports programmable SOP traces and variable-rate polarization scrambling. Additionally, when the internal polarization controller is disabled, it can function as an online polarization meter to measure the instantaneous SOP and polarization degree (DOP) of the input beam, with a data recording function that allows for long-term measurement of up to 1 billion points of polarization variation.
The wavelength range is 1480-1620nm or 1280-1340nm, with an analog bandwidth of 1 MHz and a sampling rate of up to 4M samples/second. The stable time of the generated SOP is 1ms (stable input SOP), the stability is 0.1° when the input SOP is stable, 0.5° when the input SOP changes <2π/s, and 2° when the input SOP changes <10π/s. The SOP measurement uncertainty is ±0.25° after user calibration, the DOP measurement uncertainty is ±2% after factory calibration, and ±0.5% after user calibration. The polarization extinction ratio (PER) measurement range is 0 to 40 dB, with a resolution of 0.1 dB.

同类热门仪器

友情推荐

合作客户:

查看更多>>

国产仪器:

查看更多>>

进口仪器:

查看更多>>

校准计量:

查看更多>>

联系我们

QQ

在线QQ服务

立即联系

服务热线

0755-86016691

13715327187

传真

0755-86641139-816

电子邮箱

info@wl95.com

Copyright © 2007 All Rights Reserved. 深圳市晧辰电子科技有限公司 版权所有  [粤ICP备14101712号-1] [法律顾问]

公司地址:广东省深圳市南山区西丽街道官龙村华纵科技楼5楼  邮编:518055