Product Description:
The hallmark of the MS2717A is the phase noise performance: typical -110 dBc/Hz SSB phase noise at 10 kHz offsets up to 6 GHz, which easily measures most wireless local oscillators and synthesizers. The superior dynamic range of 100 dB means fast and precise test of wireless components that require exceptional linearity. The wide 8 MHz capture bandwidth supports optional WCDMA/HSDPA RF measurements and WCDMA demodulation for testing of Node-B transmitters. Best of all, the MS2717A is ergonomically designed so controls are easy-to-learn and easy-to-use to improve productivity for manufacturing, R&D, and general purpose test.
Features:
-
Frequency range: 100 kHz to 7.1 GHz
-
Standard Built-in Preamplifier
-
Dynamic Range of 100 dB
-
Third Order Intercept: +29 dBm
-
DANL (No Preamp): –126 dBm (RBW = 10 Hz)
-
DANL (With Preamp): –150 dBm (RBW = 10 Hz)
-
Phase Noise (800 MHz): –114 dBc/Hz at 10 kHz Offset
-
Amplitude Accuracy: ±0.6 dB to 3 GHz
-
Sweep Speed: 200 ms in 10 MHz Span (RBW = 30 kHz, VBW = 10 kHz)
-
Capture Bandwidth: 8 MHz
-
Residual ACLR: –60 dB
-
Residual EVM: 1.75%
-
True RMS Detection
-
65 dB Attenuation Range, 5 dB Steps
-
20 Watt (+43 dBm) Input Protection