Product Description
The Agilent E2621A is an AC-coupled balanced adapter designed for differential communication signal testing. It supports terminating signals to 100Ω, 110Ω, or 120Ω impedances while adapting various connector types (e.g., Bantam, RJ48C, Siemens) to a 50Ω BNC input on oscilloscopes. The built-in three-way switch enables impedance selection, and the AutoProbe interface allows automatic recognition by Agilent Infiniium series oscilloscopes, ensuring test configurations align with standard requirements.
Key Features
-
Multi-Impedance Termination and Flexible Connectivity: Supports 100Ω, 110Ω, and 120Ω impedance switching, compatible with Bantam, RJ48C, Siemens, and other connectors for diverse differential communication applications.
-
Wide Bandwidth and Low Attenuation: Covers a bandwidth range from <10kHz to >100MHz, with 14dB (5X) ±0.26dB (3%) attenuation at 1MHz, ensuring signal transmission accuracy.
-
Fast Response and Low Noise: Features a rise time of <3.5ns, with AC coupling and transformer isolation to suppress DC offsets and noise interference.
-
Smart Compatibility and Automation Support: Integrates with Infiniium oscilloscopes via AutoProbe to auto-configure input impedance to 50Ω and monitor impedance settings against standard requirements.
-
High Voltage Tolerance and Safety Design: Handles differential mode AC input voltages up to 5Vrms, DC input voltages up to 200V, and common-mode voltage peaks of 300V, meeting CAT 1 safety isolation standards.