您好 欢迎来到晧辰科技!    [登录] [注册]
新闻动态全新仪器资讯论坛
快捷发布产品促销资料中心

所有设备分类

新闻动态

促销信息

产品详情

销售  

销售Ando AQ2140+AQ2732+AQ4215(131) 光波万用表+光、功率传感器模块

浏览次数:792

晧辰自营,品质保证,配送快捷

产品参数

选件 是否计量 发货周期 保修时间 成色
7天 90- 9成新
所在地 机身号 状态 资料下载
深圳市 完好
更新日期:2019-12-26
联系电话:0755-86016691

* 产品描述

Features

Sensor, sensor unit

●High accuracy
Measurement accuracy of ±2.5% is guaranteed
under the reference conditions.
●Wide wavelength range and dynamic range
Covers a wide waveband from 400 to 1870nm, and
provides a dynamic range of 100dB or more for loss
measurement. (It depends on sensors.)
●Low polarization dependence
The AQ2733 and AQ2734 Sensor Units achieve a

low polarization dependence of 0.02dBp-p or less.


Light source unit

●High stability

The LD unit has an internal isolator that maintain
optical output level stability at ±0.003dB.
●Optical power attenuation function
Optical power can be decreased in 0.1dB steps to
6.0dB. 
●Support for a variety of connectors
A wide variety of optical connectors can be used just
be exchanging the universal and connector adapters
(AQ4214 excluded).
Return loss unit
●High accuracy
Because internal self-reflectance data is stored by
individual units in memory to correct operations,
even high-reflectance attenuation can be measured
with excellent accuracy.
●High stability
The internal high-stability sensor can be used
together with the LD unit to provide stable reflectance
attenuation measurement.
●Simple operation
Mounted with a return loss unit and LD unit, the
display will show reflectance attenuation after
measurement of reference reflectance by merely
disconnecting the measured fiber cable.


Main frame

Sensor unit
●High-speed measurement
The minimum measurement interval is 10ms (single
sensor unit), improving efficiency by slashing
measurement time.
●Precise wavelength correction settings
Sensor wavelength sensitivity can be set in 1nm
steps.
●Supports three relative measurement
Measurement can be referenced to measured values
as in existing systems, or be based on a comparison
with data from other channels, or against preset
inputs.
●Selectable display resolution
Display resolution can be set to 0.1, 0.01 or 0.001,
improving reading efficiency by providing the
resolution needed for your specific application.
●Connection to external unit
By connecting extensional frame for Optical
Multimeter AQ2141, unit of up to 16 external
channels can be used. (Possible connection unit:
select one unit from Sensor unit, OPM unit, Light
source unit.)
●Data storage function
The main frame can store up to 1000 data points per
channel, or 2000 total, and user-selected data can
be output through the GP-IB interface.
●Data display function
Manual operation can be used to check not only
individual data in memory, but also maximum,
minimum and average values.
●Measurement condition set-up function
Up to ten sets of measurement conditions can be
stored for each channel and read out as required.
One set must be defined as default for each channel.


详细信息

AQ2140主机参数:


AQ2732模块参数:


AQ4215(131)模块参数:


同类热门仪器

友情推荐

合作客户:

查看更多>>

国产仪器:

查看更多>>

进口仪器:

查看更多>>

校准计量:

查看更多>>

Copyright © 2007 All Rights Reserved. 深圳市晧辰电子科技有限公司 版权所有  [粤ICP备14101712号-1] [法律顾问]

公司地址:广东省深圳市南山区西丽街道官龙村华纵科技楼5楼  邮编:518055

在线QQ服务:  服务热线:0755-86016691  电话:13715327187  传真:0755-86641139-816

E-mail:info@wl95.com